OSHA SearchOSHA records by employer

Daniels Roofing Inc.: OSHA inspections and violations

El Paso, Texas · Roofing Contractors · NAICS 238160

16inspections
16citation items
$11,678current penalties
Feb 22, 2018last inspection

Since 1987, OSHA inspectors have visited Daniels Roofing Inc. in Texas 16 times.

The most recent inspection opened on Feb 22, 2018 as a planned inspection, in El Paso.

In all, OSHA issued 16 citation items: 11 serious, 1 repeat and 4 other-than-serious.

The proposed penalties came to $23,687; today they stand at $11,678, 51% less.

The rule cited most here is 1926.501 (fall protection in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Daniels Roofing Inc. averages $1,974 across 2 cited inspections.

Daniels Roofing Inc.: OSHA citation items per year, 1987 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Daniels Roofing Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342967643 OPENED FEB 22, 2018Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 16, 2018

6040 N. Mesa, El Paso, TX 79912 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$1,247$748Feb 23, 2018Final

Inspection 341302909 OPENED MAR 4, 2016Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 29, 2016

6629 Cresta Bonita Dr., El Paso, TX 79912 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$2,000$0Mar 14, 2016Final
Citation 2, item 1
29 CFR 1926.502(h)(1)(iv) · Fall protection systems
Serious$3,200$3,200Mar 14, 2016Final

Inspection 339512006 OPENED DEC 6, 2013Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 7, 2014

12371 Edgemere, El Paso, TX 79938 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(c)(3) · Fall protection training in construction
Other-than-serious$1,500$750Mar 20, 2014Final

Inspection 338618846 OPENED JAN 31, 2013Closed

Planned · Partial · Safety · 25 employees at the site · Closed May 6, 2013

2100 Zaragoza, El Paso, TX 79938 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,700$850Apr 15, 2013Final

Inspection 336175781 OPENED SEP 4, 2012Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Sep 7, 2012

1168 Barranca, El Paso, TX 79936 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313499741 OPENED JAN 19, 2011Closed

Planned · Partial · Safety · 15 employees at the site · Closed Apr 25, 2011

725 N. Resler, El Paso, TX 79912 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$3,000$1,800Mar 31, 2011Closed

Inspection 307251892 OPENED MAR 25, 2009Closed

Planned · Partial · Safety · 7 employees at the site · Closed Oct 26, 2009

5000 Doniphan, El Paso, TX 79932 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(c) · Criteria for personal protective equipment
Serious$750$410Sep 21, 2009Closed
Citation 1, item 2
29 CFR 1926.153(g) · Liquefied petroleum gas (LP-Gas)
Serious$600$400Sep 21, 2009Closed

Inspection 307247395 OPENED JUL 13, 2006Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 22, 2006

5932 Quail, El Paso, TX 79924 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$875$500Sep 6, 2006Closed
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$525$500Sep 6, 2006Closed
8 older inspections

Inspection 301575031 OPENED AUG 5, 2003Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Aug 6, 2003

1360 George Dieter, El Paso, TX 79936 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301574406 OPENED JAN 16, 2003Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Feb 13, 2003

12401 Edgemere, El Paso, TX 79936 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301573036 OPENED FEB 27, 2002Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Apr 16, 2002

524 Thunderbird, El Paso, TX 79912 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301572095 OPENED OCT 1, 2001Closed

Planned · Partial · Safety · 19 employees at the site · Closed Apr 2, 2002

Approx 9800 Gateway N. Blvd, El Paso, TX 79934 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$4,000$1,000Nov 26, 2001Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$200Nov 26, 2001Closed

Inspection 301568473 OPENED AUG 4, 1999Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Apr 4, 2000

2001 Airway, El Paso, TX 79925 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$700Nov 10, 1999Closed

Inspection 123416786 OPENED MAY 13, 1994Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Jun 6, 1994

9375 Viscount Blvd., El Paso, TX 79925 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$300$300May 20, 1994Closed

Inspection 106803257 OPENED DEC 7, 1988Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 25, 1989

10150 Alameda Ave, El Paso, TX 79927 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$250$200Dec 21, 1988Closed

Inspection 103402442 OPENED JUN 3, 1987Closed

Planned · Complete · Safety · 13 employees at the site · Closed Jul 14, 1987

8280 Gateway East, El Paso, TX 79907 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$240$120Jun 26, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.153(g)

(g) Containers and regulating equipment installed outside of buildings or structures. Containers shall be upright upon firm foundations or otherwise firmly secured. The possible effect on the outlet piping of settling shall be guarded against by a flexible connection or special fitting.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.