OSHA SearchOSHA records by employer

David Construction One, Corp.: OSHA inspections and violations

Pompano Beach, Florida · Framing Contractors · NAICS 238130

2inspections
5citation items
$4,745current penalties
Sep 16, 2016last inspection

Since 2016, OSHA inspectors have visited David Construction One, Corp. in Florida 2 times.

The most recent inspection opened on Sep 16, 2016, in Oakland Park.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $7,909; today they stand at $4,745, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. David Construction One, Corp. averages $2,373 across 2 cited inspections.

David Construction One, Corp.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites David Construction One, Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342079621 OPENED SEP 16, 2016Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Sep 5, 2018

3721 Ne 13th Avenue, Oakland Park, FL 33334 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,173$1,304Mar 2, 2017Final
Citation 1, item 1b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Mar 2, 2017Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,173$1,304Mar 2, 2017Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Mar 2, 2017Final

Inspection 341599363 OPENED JUN 27, 2016Closed

Planned · Partial · Safety · 25 employees at the site · Closed Dec 15, 2016

1001 Nw 33rd Manor, Pompano Beach, FL 33064 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,563$2,138Sep 8, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.