OSHA SearchOSHA records by employer

David Lancaster Construction, Inc.: OSHA inspections and violations

Akron, Ohio · Siding Contractors · NAICS 238170

1inspections
4citation items
$1,940current penalties
May 7, 2018last inspection

OSHA inspectors have visited David Lancaster Construction, Inc. in Ohio one time.

It opened on May 7, 2018 as a planned inspection, in Akron.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $3,880; today they stand at $1,940, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. David Lancaster Construction, Inc. averages $1,940 across 1 cited inspection.

David Lancaster Construction, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch David Lancaster Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343140109 OPENED MAY 7, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 3, 2018

783 Mentor, Akron, OH 44303 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,880$1,940Jun 6, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 6, 2018Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jun 6, 2018Final
Citation 1, item 1d
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$0$0Jun 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.