OSHA SearchOSHA records by employer

Davin's Construction, Inc.: OSHA inspections and violations

Brooklyn, New York · Masonry Contractors · NAICS 238140

2inspections
5citation items
$11,897current penalties
Dec 13, 2019last inspection

Since 2018, OSHA inspectors have visited Davin's Construction, Inc. in New York 2 times.

The most recent inspection opened on Dec 13, 2019 on a referral, in Valley Stream.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $21,592; today they stand at $11,897, 45% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Davin's Construction, Inc. averages $5,948 across 2 cited inspections.

Davin's Construction, Inc.: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Davin's Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344774096 OPENED DEC 13, 2019Closed

Referral · Partial · Safety · 11 employees at the site · Closed Sep 28, 2023

Green Acres Shopping Mall, Valley Stream, NY 11580 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 13, 2020: Eleven employees are injured in scaffold collapse

At 8:45 a.m. on January 13, 2020, employees were performing exterior masonry on a commercial structure when a scaffold bracket broke and the scaffold collapsed. Eleven employees were injured, four of the eleven required hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$5,397$5,397Jun 8, 2020Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$5,397$0Jun 8, 2020Final

Inspection 343440962 OPENED AUG 24, 2018Closed

Referral · Partial · Safety · 8 employees at the site · Closed Jun 10, 2020

8108 13th Ave., Brooklyn, NY 11228 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,978$2,486Feb 20, 2019Final
Citation 1, item 2
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$2,842$1,528Feb 20, 2019Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,978$2,486Feb 20, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.