OSHA SearchOSHA records by employer

Day or Night Electric Inc: OSHA inspections and violations

Riddle, Oregon · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
7citation items
$5,375current penalties
Jan 26, 2016last inspection

Day or Night Electric Inc has 4 OSHA inspections on record in Oregon, the first in 2011.

OSHA's last visit started on Jan 26, 2016 as a planned inspection, in Camas Valley.

Across those inspections OSHA issued 7 citation items: 4 serious and 3 other-than-serious.

OSHA proposed $10,375 in penalties. After settlements and reviews the total is $5,375, down 48%.

Most often, OSHA cited 7010.7650, (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Day or Night Electric Inc averages $0 over 1 cited inspection in that time.

Day or Night Electric Inc: OSHA citation items per year, 2011 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

397employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Day or Night Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341205698 OPENED JAN 26, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 28, 2016

320 Baldwin St, Camas Valley, OR 97416 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-0503(2)(A)-1
Other-than-serious$0$0Mar 10, 2016Final

Inspection 316790690 OPENED JAN 8, 2013Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 26, 2013

482 Hackett Ln, Riddle, OR 97469 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 8, 2013Closed

Inspection 316790708 OPENED JAN 8, 2013Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 13, 2013

2211 Swan Hill Rd, Winston, OR 97496 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$100$100Feb 20, 2013Closed
Citation 2, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Feb 20, 2013Closed

Inspection 314750134 OPENED AUG 17, 2011Closed

Accident · Partial · Safety · 3 employees at the site · Closed May 30, 2012

5093 Riddle By Pass Rd, Riddle, OR 97469 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 14, 2011: Electric shock - direct contact with energized parts

An employee was cleaning electrical insulators. He contacted circuit parts energ ized at 13.8 kilovolts and was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(m)(3)(ii) · Electric power generation, transmission, and distribution
Serious$5,000$2,500Dec 7, 2011Final
Citation 1, item 2
29 CFR 1910.269(m)(3)(v) · Electric power generation, transmission, and distribution
Serious$5,000$2,500Dec 7, 2011Final
Citation 1, item 3 Serious$275$275Dec 7, 2011Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(m)(3)(ii)

(ii) The employer shall ensure that all switches, disconnectors, jumpers, taps, and other means through which known sources of electric energy may be supplied to the particular lines and equipment to be deenergized are open. The employer shall render such means inoperable, unless its design does not so permit, and then ensure that such means are tagged to indicate that employees are at work.

29 CFR 1910.269(m)(3)(v)

(v) Tags shall prohibit operation of the disconnecting means and shall indicate that employees are at work.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 7010.7650

Other electrical contractors and other wiring installation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.