OSHA SearchOSHA records by employer

Dbi, Inc.: OSHA inspections and violations

Cumberland, Maryland · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
5citation items
$1,187current penalties
Apr 29, 2015last inspection

Dbi, Inc. has one OSHA inspection on record in Maryland.

OSHA opened it on Apr 29, 2015 as a planned inspection, in Cumberland.

From that inspection OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA proposed $1,187 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Dbi, Inc. averages $1,187 over 1 cited inspection in that time.

Dbi, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Dbi, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340596220 OPENED APR 29, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 23, 2018

10690 Rosebriar Court Ne, Cumberland, MD 21502 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$375$375Jun 2, 2015Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$375$375Jun 2, 2015Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$437$437Jun 2, 2015Final
Citation 2, item 1
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Other-than-serious$0$0Jun 2, 2015Final
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Jun 2, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Maryland

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.