OSHA SearchOSHA records by employer

DBS Corporation Cary P Davis: OSHA inspections and violations

Lexington, Kentucky · Commercial and Institutional Building Construction · NAICS 236220

2inspections
12citation items
$53,320current penalties
Aug 14, 2025last inspection

OSHA has inspected DBS Corporation Cary P Davis 2 times in Kentucky since 2024.

The latest one began on Aug 14, 2025 as a planned inspection, in Wilder.

Those inspections ended with 12 citation items: 10 serious and 2 repeat.

Penalties were first proposed at $74,000 and now stand at $53,320, 28% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 8 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and DBS Corporation Cary P Davis averages $26,660 (2 cited inspections).

DBS Corporation Cary P Davis: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

190employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch DBS Corporation Cary P Davis and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348442708 OPENED AUG 14, 2025Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 14, 2026

5401 Alexandria Pike, Wilder, KY 41076 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$11,200$8,960Nov 26, 2025Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$11,200$8,960Nov 26, 2025Final
Citation 2, item 1
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$5,600$4,480Nov 26, 2025Final
Citation 2, item 2
29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements
Serious$5,600$4,480Nov 26, 2025Final
Citation 2, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$4,000$3,200Nov 26, 2025Final
Citation 2, item 4
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,600$4,480Nov 26, 2025Final
Citation 2, item 5
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$5,600$4,480Nov 26, 2025Final
Citation 2, item 6
29 CFR 1926.760(a)(1) · Fall protection
Serious$5,600$4,480Nov 26, 2025Final

Inspection 347809634 OPENED OCT 9, 2024Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 16, 2025

3855 Fountainblue Ln, Lexington, KY 40513 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,900$2,450Mar 12, 2025Final
Citation 1, item 2
29 CFR 1926.451(e)(4)(xii) · Scaffolds, general requirements
Serious$4,900$2,450Mar 12, 2025Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,900$2,450Mar 12, 2025Final
Citation 1, item 4
29 CFR 1926.652(g)(1)(iii) · Trench protection
Serious$4,900$2,450Mar 12, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(e)(4)(xii)

(xii) Guardrails meeting the requirements of paragraph (g)(4) of this section shall be provided on the open sides and ends of each landing.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.760 · Fall protection

Other commercial and institutional building construction employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.