OSHA SearchOSHA records by employer

De-Bar Construction LLC: OSHA inspections and violations

Gresham, Oregon · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
6citation items
$3,700current penalties
Aug 14, 2019last inspection

De-Bar Construction LLC has 2 OSHA inspections on record in Oregon, the first in 2019.

OSHA's last visit started on Aug 14, 2019 as a planned inspection, in Mcminnville, and the case has not closed yet.

Across those inspections OSHA issued 6 citation items: 2 serious, 2 repeat and 2 other-than-serious.

OSHA proposed $3,700 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.652, trench protection (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. De-Bar Construction LLC averages $1,850 over 2 cited inspections in that time.

De-Bar Construction LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

384employers cited

15 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch De-Bar Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344260872 OPENED AUG 14, 2019Open

Planned · Partial · Safety · 4 employees at the site · Open

Yamhill County Assessor Account Number 532606, Mcminnville, OR 97128 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Repeat$1,750$1,750Nov 5, 2019Final
Citation 1, item 2
29 CFR OAR 437-001-0765(1)-3
Repeat$200$200Nov 5, 2019Final
Citation 2, item 3
29 CFR 1926.652(c)(4)(iii) · Trench protection
Other-than-serious$0$0Nov 5, 2019Final

Inspection 344069364 OPENED MAY 15, 2019Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jan 6, 2020

Ne Halsey St & 238th Ave, Gresham, OR 97030 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$875$875Jul 24, 2019Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$875$875Jul 24, 2019Final
Citation 2, item 3
29 CFR OAR 437-001-0765(11)-1
Other-than-serious$0$0Jul 24, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.652(c)(4)(iii)

(iii) At least one copy of the design shall be maintained at the jobsite during construction of the protective system. After that time, the design may be stored off the jobsite, but a copy of the design shall be made available to the Secretary upon request.