Inspection 347281404 OPENED FEB 15, 2024Closed
2029 Ocean Parkway, Brooklyn, NY 11223 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2010, OSHA inspectors have visited Dears Construction, Inc. in New York 4 times.
The most recent inspection opened on Feb 15, 2024 to follow up on an earlier case, in Brooklyn.
In all, OSHA issued 9 citation items: 9 serious.
The proposed penalties came to $23,525; today they stand at $18,525, 21% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Dears Construction, Inc. averages $7,762 across 2 cited inspections.
Want to know if OSHA cites Dears Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company2029 Ocean Parkway, Brooklyn, NY 11223 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2029 Ocean Pkwy, Brooklyn, NY 11223 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $4,688 | $4,688 | Sep 26, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $3,349 | $3,349 | Sep 26, 2023 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $4,688 | $4,688 | Sep 26, 2023 | Final |
Bike Path At Canal St & Chrystie St, New York, NY 10002 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Serious | $2,000 | $1,000 | Feb 11, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $2,800 | $1,800 | Feb 11, 2016 | Final |
10 Lawrence Ave, Staten Island, NY 10314 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $1,500 | $750 | Sep 30, 2010 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $1,500 | $750 | Sep 30, 2010 | Final |
| Citation 1, item 3 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $1,500 | $750 | Sep 30, 2010 | Final |
| Citation 1, item 4 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $1,500 | $750 | Sep 30, 2010 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(6)
(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.