Decherd - Administration: OSHA inspections and violations

Decherd, Tennessee · Executive Offices · NAICS 921110

2inspections
5citation items
$0current penalties
Jun 1, 2023last inspection

Decherd - Administration has 2 OSHA inspections on record in Tennessee, the first in 2017.

OSHA's last visit started on Jun 1, 2023 as a planned inspection, in Decherd.

Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. Decherd - Administration averages $0 over 2 cited inspections in that time.

Decherd - Administration: OSHA citation items per year, 2017 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Decherd - Administration again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346742661 OPENED JUN 1, 2023Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed Aug 29, 2023

1301 West Main Street, Decherd, TN 37324 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jun 13, 2023Final

Inspection 342803152 OPENED NOV 29, 2017Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jan 11, 2018

1301 West Main Street, Decherd, TN 37324 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Dec 15, 2017Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Dec 15, 2017Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-03-.03(27)(B)6
Other-than-serious$0$0Dec 15, 2017Final
Citation 2, item 2
29 CFR TDLWD RULE 800-01-03-.04(3)(B)2
Other-than-serious$0$0Dec 15, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.