OSHA SearchOSHA records by employer

Decherd - Waste Water: OSHA inspections and violations

Decherd, Tennessee · Sewage Treatment Facilities · NAICS 221320

8inspections
21citation items
$0current penalties
Jun 24, 2021last inspection

OSHA has inspected Decherd - Waste Water 8 times in Tennessee since 1986.

The latest one began on Jun 24, 2021 as a planned inspection, in Decherd.

Those inspections ended with 21 citation items: 17 serious and 4 other-than-serious.

None of the citations carried a penalty.

Grinders and abrasive wheels comes up most often in these citations: 5 items under 1910.215.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Decherd - Waste Water averages $0 (2 cited inspections).

Decherd - Waste Water: OSHA citation items per year, 1986 to 2021
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Decherd - Waste Water and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345380554 OPENED JUN 24, 2021Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed Aug 6, 2021

325 4th Avenue South, Decherd, TN 37324 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$0$0Jul 19, 2021Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jul 19, 2021Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jul 19, 2021Final
Citation 1, item 4
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jul 19, 2021Final
Citation 1, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Jul 19, 2021Final
Citation 1, item 6
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Jul 19, 2021Final

Inspection 341326395 OPENED FEB 29, 2016Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed May 11, 2016

325 4th Avenue South, Decherd, TN 37324 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Apr 11, 2016Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Apr 11, 2016Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Apr 11, 2016Final
Citation 2, item 1
29 CFR RULE 800-01-03-.04(3)(B)2.
Other-than-serious$0$0Apr 11, 2016Final

Inspection 313116303 OPENED APR 22, 2009Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jun 4, 2009

325 4th Ave South, Decherd, TN 37324 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 9000602
Serious$0$0May 29, 2009Closed
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0May 29, 2009Closed
Citation 1, item 3
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$0$0May 29, 2009Closed
Citation 1, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0May 29, 2009Closed
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 29, 2009Closed
Citation 1, item 6
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0May 29, 2009Closed
Citation 1, item 7
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0May 29, 2009Closed
Citation 1, item 8
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0May 29, 2009Closed

Inspection 305051021 OPENED MAR 25, 2002Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed May 30, 2002

311 4th Ave. South, Decherd, TN 37324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Apr 12, 2002Closed

Inspection 114491434 OPENED NOV 30, 1993Closed

Planned · Complete · Safety · Local government · 8 employees at the site · Closed Nov 30, 1993

Baxter Lane, Decherd, TN 37324 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114503881 OPENED MAR 31, 1992Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed May 4, 1992

Baxter Lane, Decherd, TN 37324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(f)(2) · Portable fire extinguishers
Other-than-serious$0$0Apr 3, 1992Closed

Inspection 107880163 OPENED MAR 27, 1990Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed May 10, 1990

Baxter Lane, Decherd, TN 37324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Apr 19, 1990Closed

Inspection 18420950 OPENED MAR 12, 1986Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed Mar 13, 1986

Baxter Lane, Decherd, TN 37324 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(f)(2)

(2) The employer shall assure that portable extinguishers are hydrostatically tested at the intervals listed in Table L-1 of this section, except under any of the following conditions:

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(a)(4)

(4) Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other sewage treatment facilities employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.