OSHA SearchOSHA records by employer

Decisive Communications, Inc.: OSHA inspections and violations

Silver Spring, Maryland · Power and Communication Line and Related Structures Construction · NAICS 237130

5inspections
15citation items
$8,636current penalties
May 26, 2021last inspection

Since 2009, OSHA inspectors have visited Decisive Communications, Inc. in Maryland 5 times.

The most recent inspection opened on May 26, 2021 after a complaint, in Ijamsville.

In all, OSHA issued 15 citation items: 10 serious and 5 other-than-serious.

The proposed penalties came to $17,225; today they stand at $8,636, 50% less.

The rule cited most here is 1910.268 (telecommunications), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Decisive Communications, Inc. averages $1,290 across 3 cited inspections.

Decisive Communications, Inc. also files yearly injury logs with OSHA, summarized below.

Decisive Communications, Inc.: OSHA citation items per year, 2009 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Decisive Communications, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345328058 OPENED MAY 26, 2021Closed

Complaint · Partial · Safety · 137 employees at the site · Closed May 16, 2022

9416 Doctor Perry Road, Ijamsville, MD 21754 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.176(b) · Material storage and aisles
Other-than-serious$1,425$725Jul 27, 2021Final
Citation 2, item 2
29 CFR 5-503(A)
Other-than-serious$0$0Jul 27, 2021Final

Inspection 341694214 OPENED AUG 12, 2016Closed

Complaint · Partial · Health · 30 employees at the site · Closed Mar 7, 2017

9416 Doctor Perry Road, Ijamsville, MD 21754 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$2,250$1,350Dec 6, 2016Final
Citation 1, item 1b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Dec 6, 2016Final
Citation 1, item 1c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 6, 2016Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Dec 6, 2016Final
Citation 2, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 6, 2016Final
Citation 2, item 3
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Dec 6, 2016Final

Inspection 341549178 OPENED JUN 14, 2016Closed

Accident · Partial · Safety · 5 employees at the site · Closed Dec 9, 2016

Across From 5600 Stone Road, Frederick, MD 21703 · Wired and Wireless Telecommunications Carriers (except Satellite) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.268(c)(2) · Telecommunications
Serious$2,850$1,796Sep 30, 2016Final
Citation 1, item 1b
29 CFR 1910.268(c)(3) · Telecommunications
Serious$0$0Sep 30, 2016Final

Inspection 317709921 OPENED MAR 28, 2014Closed

Planned · Complete · Safety · 1 employee at the site · Closed Aug 21, 2014

8616 2nd Avenue, Silver Spring, MD 20910 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$700$490May 12, 2014Closed

Inspection 313650277 OPENED SEP 28, 2009Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Dec 18, 2009

Corner Of Aston Manor Drive And Gateshead Manor Wa, Silver Spring, MD 20904 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 25, 2009: Burn - electrical fault in underground power line

Some employees working for two contractors opened an excavation to access underg round fiber-optic cables. One of the workers located what he thought to be the t elecommunication conduit. Another conduit was approximately 75 millimeters away. The worker used a cordless drill to drill into the conduit so that he could see the line. Unfortunately, he had drilled into a 7,500-volt underground power lin e. An electrical fault occurred, and the ensuing electric arc burned the employe e's right hand, right arm, and face. He was hospitalized with first- and third d egree burns and received skin graphs on his hand. The electric arc also burned a n employee from the other contractor. He was hospitalized with first- and second -degree burns to his neck, face, and ear.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.268(c) · Telecommunications
Serious$2,750$1,195Oct 28, 2009Closed
Citation 1, item 2
29 CFR 1910.268(e) · Telecommunications
Serious$2,750$1,195Oct 28, 2009Closed
Citation 1, item 3
29 CFR 1910.268(f)(1) · Telecommunications
Serious$2,750$1,195Oct 28, 2009Closed
Citation 1, item 4
29 CFR 1926.651(b)(1) · Excavations
Serious$1,750$690Oct 28, 2009Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Ijamsville site logged 9 recordable injuries or illnesses among about 144 workers: 6.5 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 181 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Decisive Communications Inc.
Ijamsville · 2025
144 936.51.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(a)(2)

(2) Guard design. The safety guard shall cover the spindle end, nut, and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard, except:

29 CFR 1910.215(a)(4)

(4) Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.268 · Telecommunications

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.651 · Excavations

Other power and communication line and related structures construction employers in Maryland