OSHA SearchOSHA records by employer

Deep Woods Carpentry LLC: OSHA inspections and violations

Denver, Colorado · Finish Carpentry Contractors · NAICS 238350

1inspections
2citation items
$1,800current penalties
Sep 26, 2018last inspection

Deep Woods Carpentry LLC has one OSHA inspection on record in Colorado.

OSHA opened it on Sep 26, 2018 after a complaint, in Denver.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,772 in penalties. After settlements and reviews the total is $1,800, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Deep Woods Carpentry LLC averages $1,800 over 1 cited inspection in that time.

Deep Woods Carpentry LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Deep Woods Carpentry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343493128 OPENED SEP 26, 2018Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Nov 16, 2020

3131 W Mexico Avenue, Denver, CO 80219 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,772$1,800Oct 9, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Oct 9, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.