OSHA SearchOSHA records by employer

Defalco Construction Inc.: OSHA inspections and violations

Flushing, New York · Structural Steel and Precast Concrete Contractors · NAICS 238120

4inspections
4citation items
$39,256current penalties
Sep 7, 2023last inspection

OSHA has inspected Defalco Construction Inc. 4 times in New York since 2020.

The latest one began on Sep 7, 2023, in Rego Park; the case is still open.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $39,256 and still stand at $39,256.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Defalco Construction Inc. averages $19,628 (2 cited inspections).

It reported 1 severe injury to OSHA since 2015.

Defalco Construction Inc.: OSHA citation items per year, 2020 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Defalco Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346960586 OPENED SEP 7, 2023Open

Unprogrammed other · Complete · Safety · 77 employees at the site · Open

98-14 66th Avenue, Rego Park, NY 11374 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$9,218$9,218Feb 28, 2024Final
Citation 1, item 2
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$9,218$9,218Feb 28, 2024Final

Inspection 346183460 OPENED AUG 31, 2022Closed

Planned · Complete · Health · 34 employees at the site · Closed Jan 31, 2023

35-32 Leavitt Street, Flushing, NY 11358 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346183569 OPENED AUG 31, 2022Closed

Unprogrammed other · Partial · Safety · 44 employees at the site · Closed Feb 28, 2023

35-32 Leavitt Street, Flushing, NY 11354 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344546700 OPENED JAN 8, 2020Closed

Referral · Partial · Safety · 8 employees at the site · Closed Apr 23, 2026

16 East 34th Street, New York, NY 10016 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$8,675$8,675Mar 23, 2020Final
Citation 1, item 2
29 CFR 1926.452(w)(6)(i) · Rules for each type of scaffold
Serious$12,145$12,145Mar 23, 2020Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Aug 1, 2022, Flushing: Hospitalization · soreness, pain, hurt-nonspecified injury · leg(s), unspecified

While carrying column bracers, an employee was climbing a ladder from the 10th floor of a building to the 11th floor. The employee's leg got caught in the ladder and they sustained a leg injury.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(w)(6)(i)

(i) The surface on which the scaffold is being moved is within 3 degrees of level, and free of pits, holes, and obstructions;

29 CFR 1926.502 · Fall protection systems

Other structural steel and precast concrete contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.