Inspection 346559982 OPENED MAR 6, 2023Closed
1968 Gilbert Street, Norfolk, VA 23511 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Portsmouth, Virginia · General Warehousing and Storage · NAICS 493110
OSHA has inspected Defense Logistics Agency Distribution 3 times in Virginia since 2017.
The latest one began on Mar 6, 2023 after a complaint, in Norfolk.
Those inspections ended with 4 citation items: 3 serious and 1 other-than-serious.
None of the citations carried a penalty.
How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $3,555, and Defense Logistics Agency Distribution averages $0 (2 cited inspections).
Virginia · latest 90 days of OSHA records
250employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Defense Logistics Agency Distribution and get notified the morning OSHA posts a new citation for it.
Watch this company1968 Gilbert Street, Norfolk, VA 23511 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Norfolk Naval Shipyard Building 276, Portsmouth, VA 23709 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $0 | $0 | Apr 23, 2018 | Final |
Norfolk Naval Shipyard Portsmouth Building 276, Portsmouth, VA 23709 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.213(i)(1) · Woodworking machinery |
Serious | $0 | $0 | Oct 18, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 18, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Oct 18, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.213(i)(1)
(i) Bandsaws and band resaws. (1) All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall
29 CFR 1910.303(b)(1)
(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:
29 CFR 1910.304(g)(5)
(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.