Inspection 341106623 OPENED DEC 9, 2015Closed
2415 Schuster Dr., Hyattsville, MD 20781 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $1,750 | $1,103 | Mar 15, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(5)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 1d 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts |
Serious | $1,500 | $810 | Mar 15, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $875 | $551 | Mar 15, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $1,250 | $675 | Mar 15, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(7)(iv) · Lockout/tagout |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.305(b)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 2, item 4 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |