Inspection 341940393 OPENED OCT 3, 2016Closed
75 Norman Avenue, Delran, NJ 08075 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Delran, New Jersey · Sewage Treatment Facilities · NAICS 221320
Delran Sewer Utility Pump Stations has 2 OSHA inspections on record in New Jersey, the first in 2016.
OSHA's last visit started on Oct 3, 2016 to follow up on an earlier case, in Delran.
Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.
OSHA proposed $7,000 in penalties and the amount has not been reduced.
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Delran Sewer Utility Pump Stations averages $7,000 over 1 cited inspection in that time.
New Jersey · latest 90 days of OSHA records
276employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Delran Sewer Utility Pump Stations and get notified the morning OSHA posts a new citation for it.
Watch this company75 Norman Avenue, Delran, NJ 08075 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
75 Norman Avenue, Delran, NJ 08075 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $2,800 | $2,800 | Sep 8, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $3,500 | $3,500 | Sep 8, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $700 | $700 | Sep 8, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.146(c)(2)
(2) If the workplace contains permit spaces, the employer shall inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.