OSHA SearchOSHA records by employer

Depersia Corp.: OSHA inspections and violations

Avon, Connecticut · Masonry Contractors · NAICS 238140

8inspections
8citation items
$5,235current penalties
Apr 7, 2016last inspection

OSHA has inspected Depersia Corp. 8 times in Connecticut since 1993.

The latest one began on Apr 7, 2016, in Branford.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $8,975 and now stand at $5,235, 42% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Depersia Corp. averages $2,880 (1 cited inspection).

Depersia Corp.: OSHA citation items per year, 1993 to 2016
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Depersia Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341429967 OPENED APR 7, 2016Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Aug 2, 2016

694 West Main Street Building 1, Branford, CT 06405 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$1,680Jun 8, 2016Final
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,000$1,200Jun 8, 2016Final

Inspection 314405465 OPENED MAY 20, 2011Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed May 20, 2011

175 Fresh Water Blvd., Enfield, CT 06082 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311782205 OPENED NOV 12, 2009Closed

Unprogrammed related · Complete · Safety · 15 employees at the site · Closed Feb 17, 2010

5 Dayton Place, Waterford, CT 06385 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,500$750Jan 19, 2010Closed

Inspection 123158586 OPENED SEP 21, 2004Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jan 13, 2005

15 Controls Drive, Shelton, CT 06484 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$800$480Dec 22, 2004Closed

Inspection 109845537 OPENED DEC 12, 2000Closed

Referral · Partial · Safety · 20 employees at the site · Closed Jan 18, 2001

210 New Britain Avenue, Plainville, CT 06062 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$1,500$750Jan 8, 2001Closed

Inspection 109849729 OPENED JAN 21, 1999Closed

Referral · Partial · Safety · 7 employees at the site · Closed Mar 22, 1999

Route 44, Nod Brook, Avon, CT 06001 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109856203 OPENED JUL 25, 1996Closed

Referral · Partial · Safety · 14 employees at the site · Closed Aug 28, 1996

1852 East Main Street, Torrington, CT 06790 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(6) · Scaffolds, general requirements
Serious$375$375Aug 7, 1996Closed
Citation 1, item 1b
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$0$0Aug 7, 1996Closed
Citation 1, item 1c
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0Aug 7, 1996Closed

Inspection 123212797 OPENED SEP 17, 1993Closed

Planned · No inspection · Safety · Closed Sep 17, 1993

Route 44, Nod Brook, Avon, CT 06001 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(d)(10)

(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist:

29 CFR 1926.451(d)(6)

(6) When winding drum hoists are used on a suspension scaffold, they shall contain not less than four wraps of the suspension rope at the lowest point of scaffold travel. When other types of hoists are used, the suspension ropes shall be long enough to allow the scaffold to be lowered to the level below without the rope end passing through the hoist, or the rope end shall be configured or provided with means to prevent the end from passing through the hoist.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.706 · Requirements for masonry construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.