Inspection 347740359 OPENED SEP 5, 2024Closed
712 Mckinley Avenue, Rome, NY 13440 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Deraway Construction 2 times in New York since 2024.
The latest one began on Sep 5, 2024, in Rome.
Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.
Penalties were first proposed at $13,875 and now stand at $3,874, 72% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Deraway Construction averages $3,874 (1 cited inspection).
Want to know if OSHA cites Deraway Construction again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company712 Mckinley Avenue, Rome, NY 13440 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
418 Roberts Street, Rome, NY 13440 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.454(c)(3) · Scaffold training |
Serious | $4,965 | $3,476 | Feb 21, 2025 | Final |
| Citation 1, item 1b 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $0 | $0 | Feb 21, 2025 | Final |
| Citation 1, item 1c 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Feb 21, 2025 | Final |
| Citation 1, item 1d 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $4,965 | $0 | Feb 21, 2025 | Final |
| Citation 1, item 1e 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $3,547 | $0 | Feb 21, 2025 | Final |
| Citation 1, item 1f 29 CFR 1926.1053(b)(5)(i) · Ladders in construction |
Serious | $0 | $0 | Feb 21, 2025 | Final |
| Citation 2, item 1 29 CFR 1903.19(d)(1) · Proving cited hazards were fixed |
Other-than-serious | $398 | $398 | Sep 25, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1903.19(d)(1)
(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(5)(i)
(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.