Dexter Lott: OSHA inspections and violations

Savannah, Georgia · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,260current penalties
Aug 17, 2017last inspection

OSHA has inspected Dexter Lott once in Georgia.

The inspection began on Aug 17, 2017 as a planned inspection, in Savannah.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,519 and now stand at $3,260, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dexter Lott averages $3,260 (1 cited inspection).

Dexter Lott: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Dexter Lott again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342567385 OPENED AUG 17, 2017Closed

Planned · Partial · Safety · 7 employees at the site · Closed Oct 6, 2017

241 Randolph St., Savannah, GA 31401 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,173$1,086Sep 7, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,173$1,086Sep 7, 2017Final
Citation 1, item 3
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,173$1,086Sep 7, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.