OSHA SearchOSHA records by employer

Deyvin's Construction, Inc.: OSHA inspections and violations

Malden, Massachusetts · Siding Contractors · NAICS 238170

1inspections
4citation items
$1,000current penalties
Jul 22, 2019last inspection

Deyvin's Construction, Inc. has one OSHA inspection on record in Massachusetts.

OSHA opened it on Jul 22, 2019 as a planned inspection, in Malden.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $3,978 in penalties. After settlements and reviews the total is $1,000, down 75%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Deyvin's Construction, Inc. averages $1,000 over 1 cited inspection in that time.

Deyvin's Construction, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

249employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Deyvin's Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344209200 OPENED JUL 22, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 30, 2020

60 Oliver St., Malden, MA 02148 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,978$1,000Sep 30, 2019Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Sep 30, 2019Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 30, 2019Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$0$0Sep 30, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other siding contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.