OSHA SearchOSHA records by employer

Dezurik Apco Hilton: OSHA inspections and violations

Hollywood, Florida · Industrial Valve Manufacturing · NAICS 332911

1inspections
3citation items
$13,260current penalties
Aug 28, 2019last inspection

OSHA has inspected Dezurik Apco Hilton once in Florida.

The inspection began on Aug 28, 2019 on a referral, in Hollywood.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $13,260 and still stand at $13,260.

Lockout/tagout comes up most often in these citations: 3 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dezurik Apco Hilton averages $13,260 (1 cited inspection).

Dezurik Apco Hilton: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Dezurik Apco Hilton and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344270368 OPENED AUG 28, 2019Closed

Referral · Partial · Safety · 377 employees at the site · Closed Jan 30, 2020

2600 N. 64th Avenue, Hollywood, FL 33024 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 22, 2019: Employee's hands are amputated while reinstalling water main

At 2:30 p.m. on August 22, 2019, an employee was reinstalling/assembling a water main/well pump surge relief valve. The employer did not have lockout/tagout procedures to dissemble the damaged valve and attempted to do so while the valve spring was still loaded (energy not dissipated). The employee placed his hands inside the valve, in an attempt to tighten a retaining collar/component of the valve, and overtightened the component, causing the component to break, which allowed the spring to pin both of his hands to the top of the valve. This crushed both of his hands, and the employee was hospitalized for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$13,260$13,260Dec 4, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Dec 4, 2019Final
Citation 1, item 1c
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Dec 4, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: