OSHA SearchOSHA records by employer

DH Underground Inc.: OSHA inspections and violations

El Paso, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
3citation items
$2,673current penalties
Mar 1, 2018last inspection

Since 2003, OSHA inspectors have visited DH Underground Inc. in Texas 5 times.

The most recent inspection opened on Mar 1, 2018 as a planned inspection, in El Paso.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $4,722; today they stand at $2,673, 43% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. DH Underground Inc. averages $1,153 across 1 cited inspection.

DH Underground Inc.: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch DH Underground Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342984325 OPENED MAR 1, 2018Closed

Planned · Partial · Safety · 23 employees at the site · Closed Apr 25, 2018

6040 N. Mesa, El Paso, TX 79912 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,922$1,153Mar 29, 2018Final

Inspection 341823383 OPENED OCT 6, 2016Closed

Planned · Complete · Safety · 25 employees at the site · Closed Nov 10, 2016

Corner Of Biggs And Msg R Miller Streets, Fort Bliss, TX 79916 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339789166 OPENED MAY 30, 2014Closed

Planned · Complete · Safety · 20 employees at the site · Closed Oct 2, 2014

Fountain And N. Mesa, El Paso, TX 79912 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$1,600$800Sep 12, 2014Final

Inspection 337768618 OPENED DEC 4, 2012Closed

Planned · Partial · Safety · 20 employees at the site · Closed May 29, 2013

10498 Dyer, El Paso, TX 79924 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$1,200$720May 13, 2013Final

Inspection 301574992 OPENED JUL 31, 2003Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 1, 2003

Intersection Of Mesa & Champion Place, El Paso, TX 79912 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(g)(1)(i)

(i) Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.