OSHA SearchOSHA records by employer

DI Franco Masonry Inc.: OSHA inspections and violations

Westminster, Colorado · Masonry Contractors · NAICS 238140

2inspections
11citation items
$20,280current penalties
Jan 11, 2022last inspection

DI Franco Masonry Inc. has 2 OSHA inspections on record in Colorado, the first in 2013.

OSHA's last visit started on Jan 11, 2022 on a referral, in Denver.

Across those inspections OSHA issued 11 citation items: 11 serious.

OSHA proposed $30,555 in penalties. After settlements and reviews the total is $20,280, down 34%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (8 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. DI Franco Masonry Inc. averages $15,000 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

DI Franco Masonry Inc.: OSHA citation items per year, 2013 to 2022
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

138employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch DI Franco Masonry Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345718019 OPENED JAN 11, 2022Closed

Referral · Partial · Safety · 2 employees at the site · Closed Nov 16, 2022

1842 S Ogden St., Denver, CO 80210 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 7, 2022: Two employees fall from scaffold and receive fractures

At 4:00 p.m. on January 7, 2022, Employee #1 and Employee #2 worked from a scaffold to install precast chimney caps on a new chimney. Both employees were working on the same deck and were raising a chimney cap (weighing approximately eighty pounds) when the scaffold plank failed and both employees fell approximately twenty-eight feet. Employee #1 received a leg fracture and Employee #2 received rib fractures. Both employees were taken to the hospital and admitted for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$4,351$3,000Jun 3, 2022Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,351$3,000Jun 3, 2022Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,351$3,000Jun 3, 2022Final
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,351$3,000Jun 3, 2022Final
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$4,351$3,000Jun 3, 2022Final

Inspection 339267460 OPENED AUG 6, 2013Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Feb 6, 2015

7151 N. Federal Blvd, Westminster, CO 80030 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$1,680Aug 12, 2013Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,600$960Aug 12, 2013Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 12, 2013Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$1,680Aug 12, 2013Final
Citation 1, item 4a
29 CFR 1926.454(a) · Scaffold training
Serious$1,600$960Aug 12, 2013Final
Citation 1, item 4b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Aug 12, 2013Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 7, 2022, Denver: Hospitalization · fractures · leg(s), unspecified

Two employees were repairing a chimney cap on the roof of a home. A scaffolding plank the employees were standing on broke. The employees both fell 28 feet, one suffering a broken leg and the other suffering broken ribs. Both were hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.