Inspection 347443897 OPENED APR 26, 2024Closed
Corner Of Solar Street And West Division Street, Syracuse, NY 13204 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected DI Peso Contractors Inc 3 times in New York since 2021.
The latest one began on Apr 26, 2024 as a planned inspection, in Syracuse.
Those inspections ended with 5 citation items: 5 serious.
Penalties were first proposed at $9,948 and now stand at $6,964, 30% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and DI Peso Contractors Inc averages $6,964 (1 cited inspection).
New York · latest 90 days of OSHA records
372employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch DI Peso Contractors Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyCorner Of Solar Street And West Division Street, Syracuse, NY 13204 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
St. Joseph's Hospital Parking Ramp 301 Prospect Avenue, Syracuse, NY 13203 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Afton Central School District Bus Garage Route 7, Afton, NY 13730 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements |
Serious | $3,511 | $2,458 | Jan 10, 2022 | Final |
| Citation 1, item 1b 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Jan 10, 2022 | Final |
| Citation 1, item 1c 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Jan 10, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $2,926 | $2,048 | Jan 10, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.1153(c)(1) · Silica dust in construction |
Serious | $3,511 | $2,458 | Jan 10, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1153(c)(1)
(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.
29 CFR 1926.451(e)(9)(iv)
(iv) Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.
29 CFR 1926.451(f)(7)
(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.