Inspection 317202679 OPENED DEC 6, 2013Closed
Accident · Partial · Safety · 6 employees at the site · Closed Aug 1, 2014
2900 Stoneridge Drive, Pleasanton, CA 94588 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
Incident on Dec 3, 2013: Worker falls into trench and injures neck
At approximately 3:00 p.m. on December 3, 2013, Employee #1, an apprentice labor er employed by Diablo Plumbing, Inc., and Coworkers #1 and #2, managers, were wo rking at a multi-employer work site, the construction of the Stoneridge Creek Sk illed Nursing Facility. Employee #1's employer was subcontracted to Segue Constr uction, Inc., the general contractor, to install underground plumbing and relate d plumbing trenches. The employer's workers had excavated a relatively shallow s ewer trench, approximately 2 feet 6 inches deep. They then set the pipe in the t rench. Their work progressed toward one end of the site, while another contracto r followed behind to excavate a deeper trench and install in it the electrical u tility. Employee #1 was instructed by Coworker #1, a manager, to drop back to ar eas where the sewer pipe had been recently installed and to tape plastic sleevin g for corrosion protection to the 4-inch sanitary sewer riser. Due to the config uration of site utilities, there were several locations where the sewer and elec trical trenches crossed. One of these locations was Grid Line 8, between Grid Li nes M and N, where the electrical trench had been excavated crosswise to the sew er trench and approximately 3 feet from the sewer riser. The work was scheduled so that the excavation activities of the two trades were not physically conflict ing. Employee #1 worked safely within the sewer trench, installing the plastic s leeving. He then exited the shallow trench to retrieve more tape. He climbed out of the sewer trench at the corner where it intersected with the deeper electric al trench. The corner broke off, and Employee #1 fell into the deeper electrical trench, a fall height of 7 feet. Although Employee #1 climbed out of the trench on his own, he was gasping for breath. Coworker #2 came over and evaluated Empl oyee #1. Coworker #1 called for an ambulance after Employee #1 lost consciousnes s. The Livermore-Pleasanton Fire Department responded and transported Employee # 1 to the hospital, where he was admitted and treated for bruising to the neck. T his event was reported to Cal/OSHA by the employer at approximately 3:00 p.m. on December 3, 2013. It also was reported by the general contractor and the Liverm ore-Pleasanton Fire Department. During Cal/OSHA's subsequent investigation, it w as determined that Diablo Plumbing was a plumbing contractor that performed work on a wide range of both residential and commercial projects, including related excavation work. The investigation report concluded that the employer had failed to reevaluate the trench conditions when the situation changed. The top edges a nd corners of the trench were beveled in many places from drying and cracking an d/or minor sloughing. Where the newer, deeper electrical conduit trench was exca vated at right angles to the sewer trench, the drying reentrant corners where th e trenches met constituted a new hazard to Employee #1, who was working in one o f these areas. The employer had failed to train Employee #1 to recognize and avo id this new hazard. The investigation found that Employee #1 could have avoided the new hazard if he had walked further away from the deeper electrical utility trench before exiting the shallower sewer trench.