OSHA SearchOSHA records by employer

Diamante Concrete, Inc.: OSHA inspections and violations

Fort Lauderdale, Florida · Roofing Contractors · NAICS 238160

5inspections
11citation items
$64,110current penalties
Mar 9, 2021last inspection

Since 2018, OSHA inspectors have visited Diamante Concrete, Inc. in Florida 5 times.

The most recent inspection opened on Mar 9, 2021 after a complaint, in Fort Lauderdale.

In all, OSHA issued 11 citation items: 8 serious, 2 repeat and 1 other-than-serious.

The proposed penalties came to $76,180; today they stand at $64,110, 16% less.

The rule cited most here is 1926.501 (fall protection in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Diamante Concrete, Inc. averages $12,822 across 5 cited inspections.

Diamante Concrete, Inc.: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Diamante Concrete, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345186852 OPENED MAR 9, 2021Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Apr 4, 2024

534 Nw 22 Avenue River Garden Townhouses, Fort Lauderdale, FL 33311 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$2,574$2,574Sep 3, 2021Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,574$2,574Sep 3, 2021Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$21,457$21,457Sep 3, 2021Final

Inspection 343451035 OPENED SEP 7, 2018Closed

Planned · Partial · Safety · 28 employees at the site · Closed Dec 26, 2023

2980 N. Federal Highway, Fort Lauderdale, FL 33306 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,834$5,834Mar 6, 2019Final
Citation 1, item 1b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Mar 6, 2019Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$744$744Sep 23, 2019Final

Inspection 343444022 OPENED SEP 5, 2018Closed

Referral · Partial · Safety · 2 employees at the site · Closed Nov 25, 2019

2980 N Federal Highway, Fort Lauderdale, FL 33306 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$19,918$13,942Nov 7, 2018Final
Citation 2, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$9,959$6,971Nov 7, 2018Final

Inspection 343437166 OPENED SEP 4, 2018Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Dec 30, 2019

6257 Se Fauna Terrace, Hobe Sound, FL 33455 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,174$3,621Sep 21, 2018Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,174$3,621Sep 21, 2018Final

Inspection 343072120 OPENED MAR 7, 2018Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Nov 5, 2018

6127 Yerba Buena Court, Lake Worth, FL 33467 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,772$2,772Aug 14, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.