OSHA SearchOSHA records by employer

Diamante Construction LLC: OSHA inspections and violations

East Hanover, New Jersey · Siding Contractors · NAICS 238170

1inspections
2citation items
$5,000current penalties
Jul 30, 2025last inspection

OSHA inspectors have visited Diamante Construction LLC in New Jersey one time.

It opened on Jul 30, 2025 after a complaint, in East Hanover and is still open.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $7,944; today they stand at $5,000, 37% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Diamante Construction LLC averages $5,000 across 1 cited inspection.

Diamante Construction LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

264employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Diamante Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348405788 OPENED JUL 30, 2025Open

Complaint · Partial · Safety · 4 employees at the site · Open

49 Ventura Drive, East Hanover, NJ 07936 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,972$2,500Jan 29, 2026Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,972$2,500Jan 29, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other siding contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.