Diamond Brown Plastering and Stucco: OSHA inspections and violations

Denver, Colorado · Other Building Finishing Contractors · NAICS 238390

1inspections
1citation items
$0current penalties
Sep 30, 2015last inspection

Diamond Brown Plastering and Stucco has one OSHA inspection on record in Colorado.

OSHA opened it on Sep 30, 2015 after a complaint, in Denver.

From that inspection OSHA issued 1 citation item: 1 other-than-serious.

OSHA did not attach a penalty to any of these citations.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Diamond Brown Plastering and Stucco averages $0 over 1 cited inspection in that time.

Diamond Brown Plastering and Stucco: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Diamond Brown Plastering and Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340953611 OPENED SEP 30, 2015Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 6, 2015

3236 Federal Blvd., Denver, CO 80212 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Oct 27, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

Other other building finishing contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.