Inspection 347529760 OPENED MAY 31, 2024Closed
18300 Conneaut Lake Rd., Meadville, PA 16335 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Erie, Pennsylvania · All Other Specialty Trade Contractors · NAICS 238990
Diamond Design Construction, Inc. has 7 OSHA inspections on record in Pennsylvania, the first in 2011.
OSHA's last visit started on May 31, 2024, in Meadville.
Across those inspections OSHA issued 11 citation items: 11 serious.
OSHA proposed $16,841 in penalties. After settlements and reviews the total is $14,041, down 17%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Diamond Design Construction, Inc. averages $3,741 over 1 cited inspection in that time.
Pennsylvania · latest 90 days of OSHA records
287employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Diamond Design Construction, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company18300 Conneaut Lake Rd., Meadville, PA 16335 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 Scotland Road Edinboro University Of Pennsylvania, Highlands 4, Edinboro, PA 16444 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5942 Peach St., Erie, PA 16509 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8033 Oliver Road, Erie, PA 16509 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements |
Serious | $3,741 | $3,741 | Sep 28, 2016 | Final |
| Citation 1, item 1b 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 28, 2016 | Final |
1120 Market St., Meadville, PA 16335 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1964 E. 18th Street, Erie, PA 16510 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $1,200 | $1,200 | Sep 27, 2013 | Final |
| Citation 1, item 1b 29 CFR 1926.451(h)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 27, 2013 | Final |
| Citation 1, item 2 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $2,000 | $2,000 | Sep 27, 2013 | Final |
| Citation 1, item 3 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $2,000 | $2,000 | Sep 27, 2013 | Final |
| Citation 1, item 4a 29 CFR 1926.452(n)(1) · Rules for each type of scaffold |
Serious | $1,200 | $1,200 | Sep 27, 2013 | Final |
| Citation 1, item 4b 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $0 | $0 | Sep 27, 2013 | Final |
| Citation 1, item 5 29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements |
Serious | $1,600 | $1,600 | Sep 27, 2013 | Final |
| Citation 1, item 6 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $1,600 | $1,600 | Sep 27, 2013 | Final |
260 W. State Street, Sharon, PA 16146 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $3,500 | $700 | Feb 3, 2012 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.1053(b)(4)
(4) Ladders shall be used only for the purpose for which they were designed.
29 CFR 1926.403(b)(2)
(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.