OSHA SearchOSHA records by employer

Diaz Roofing: OSHA inspections and violations

El Paso, Texas · Roofing Contractors · NAICS 238160

6inspections
10citation items
$20,442current penalties
Jun 24, 2021last inspection

Diaz Roofing has 6 OSHA inspections on record in Texas, the first in 2004.

OSHA's last visit started on Jun 24, 2021 as a planned inspection, in Corpus Christi.

Across those inspections OSHA issued 10 citation items: 8 serious and 2 repeat.

OSHA proposed $21,437 in penalties. After settlements and reviews the total is $20,442, down 5%.

Most often, OSHA cited 1926.501, fall protection in construction (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Diaz Roofing averages $1,492 over 1 cited inspection in that time.

Diaz Roofing: OSHA citation items per year, 2004 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Diaz Roofing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345384887 OPENED JUN 24, 2021Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 8, 2021

538 S Tancahua, Corpus Christi, TX 78401 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,487$1,492Sep 27, 2021Final

Inspection 315098939 OPENED NOV 1, 2010Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 30, 2013

Expressway 83 & 2d St, Mcallen, TX 78501 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$3,000Jan 12, 2011Closed

Inspection 307251579 OPENED FEB 13, 2009Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 17, 2015

12255 Stansbury, El Paso, TX 79938 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,400$1,400Apr 10, 2009Closed
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$10,000$10,000Apr 10, 2009Closed

Inspection 307246371 OPENED FEB 28, 2006Closed

Referral · Partial · Safety · 4 employees at the site · Closed Mar 22, 2007

517 Phil Hansen Dr., Canutillo, TX 79835 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$2,000$2,000Mar 9, 2006Closed

Inspection 307245340 OPENED AUG 31, 2005Closed

Referral · Partial · Safety · 4 employees at the site · Closed Mar 22, 2007

728 Phil Hansen Dr., Canutillo, TX 79835 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$600$600Dec 29, 2005Closed
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Dec 29, 2005Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$750Dec 29, 2005Closed
Citation 1, item 3
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$600$600Dec 29, 2005Closed
Citation 1, item 4
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$600$600Dec 29, 2005Closed

Inspection 301576708 OPENED JAN 20, 2004Closed

Planned · Partial · Safety · 4 employees at the site · Closed Feb 24, 2004

3200 Block/joe Battle Blvd., El Paso, TX 79936 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(6)

(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.