Inspection 345334692 OPENED MAY 28, 2021Closed
Old Bp Gas Station And Car Wash 9159 Chamberlayne Road, Mechanicsville, VA 23116 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Dickerson Construction LLC 5 times in Virginia since 2014.
The latest one began on May 28, 2021 as a planned inspection, in Mechanicsville.
Those inspections ended with 9 citation items: 6 serious and 3 other-than-serious.
Penalties were first proposed at $4,535 and now stand at $2,736, 40% lower after settlements or reviews.
Trench protection comes up most often in these citations: 2 items under 1926.652.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dickerson Construction LLC averages $940 (2 cited inspections).
Virginia · latest 90 days of OSHA records
253employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Dickerson Construction LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyOld Bp Gas Station And Car Wash 9159 Chamberlayne Road, Mechanicsville, VA 23116 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
20061 Timberlake Road 8209 Timberlake Road, Lynchburg, VA 24501 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
130 Towne Center W. Blvd, Richmond, VA 23233 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $1,235 | $864 | Jun 17, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.652(b)(1)(i) · Trench protection |
Serious | $1,235 | $864 | Jun 17, 2019 | Final |
Wayside Ave & Harris Street, Amelia Court House, VA 23002 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.152(g)(9) · Flammable liquids |
Other-than-serious | $315 | $150 | Sep 30, 2015 | Final |
| Citation 1, item 1b 29 CFR 1926.152(g)(11) · Flammable liquids |
Other-than-serious | $0 | $0 | Sep 30, 2015 | Final |
3166 W. Cary Street, Richmond, VA 23219 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(b) · Hard hats in construction |
Other-than-serious | $525 | $0 | Aug 13, 2014 | Closed |
| Citation 1, item 2a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $525 | $368 | Aug 13, 2014 | Closed |
| Citation 1, item 2b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | Aug 13, 2014 | Closed |
| Citation 1, item 3a 29 CFR 1926.651(c)(2) · Excavations |
Serious | $700 | $490 | Aug 13, 2014 | Closed |
| Citation 1, item 3b 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $0 | $0 | Aug 13, 2014 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.152(g)(11)
(11) Each service or fueling area shall be provided with at least one fire extinguisher having a rating of not less than 20-B:C located so that an extinguisher will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service area.
29 CFR 1926.152(g)(9)
(9) Conspicuous and legible signs prohibiting smoking shall be posted.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.