OSHA SearchOSHA records by employer

Diesslin Structures, Inc: OSHA inspections and violations

Salida, Colorado · Commercial and Institutional Building Construction · NAICS 236220

6inspections
18citation items
$22,500current penalties
May 26, 2022last inspection

OSHA has inspected Diesslin Structures, Inc 6 times in Colorado since 2004.

The latest one began on May 26, 2022 after a complaint, in Salida.

Those inspections ended with 18 citation items: 12 serious and 6 other-than-serious.

Penalties were first proposed at $47,027 and now stand at $22,500, 52% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 12 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Diesslin Structures, Inc averages $12,000 (1 cited inspection).

Diesslin Structures, Inc also files yearly injury logs with OSHA, summarized below.

Diesslin Structures, Inc: OSHA citation items per year, 2004 to 2022
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

134employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Diesslin Structures, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346031073 OPENED MAY 26, 2022Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Sep 26, 2022

10955 Cr 128, Salida, CO 81201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$10,151$6,000Aug 25, 2022Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 25, 2022Final
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 25, 2022Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$10,151$6,000Aug 25, 2022Final

Inspection 339545790 OPENED JAN 7, 2014Closed

Complaint · Partial · Safety · 45 employees at the site · Closed Jan 7, 2014

516 Main St, Buena Vista, CO 81211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 330631508 OPENED JUN 3, 2011Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jun 3, 2011

150 Miller Rd., Edwards, CO 81632 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309195469 OPENED AUG 12, 2008Closed

Planned · Partial · Safety · 8 employees at the site · Closed Nov 18, 2008

101 W. Hwy 50, Salida, CO 81201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$700$500Oct 8, 2008Closed
Citation 1, item 2
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$875$500Oct 8, 2008Closed
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$525$500Oct 8, 2008Closed
Citation 2, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$15,000$5,000Oct 8, 2008Closed
Citation 2, item 1b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Oct 8, 2008Closed
Citation 2, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,000$1,000Oct 8, 2008Closed

Inspection 309192334 OPENED FEB 6, 2006Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 18, 2006

131 Lenderman, Buena Vista, CO 81211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$875$200Mar 22, 2006Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$625$300Mar 22, 2006Final
Citation 1, item 6a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$500Mar 22, 2006Final
Citation 1, item 6b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Other-than-serious$0$0Mar 22, 2006Final

Inspection 307648998 OPENED JUL 13, 2004Closed

Referral · Partial · Safety · 4 employees at the site · Closed Sep 24, 2004

7600 W. Hwy. 50, Salida, CO 81201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$1,750$700Jul 30, 2004Closed
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,500$1,000Jul 30, 2004Closed
Citation 1, item 2b
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$0$0Jul 30, 2004Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$875$300Jul 30, 2004Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Salida site logged 3 recordable injuries or illnesses among about 39 workers: 8.4 per 100 full-time workers, against a median of 0.6 for its industry. Those cases cost 9 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Diesslin Structures Inc
Salida · 2025
39 318.40.6

Included with any plan: 4 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.