OSHA SearchOSHA records by employer

Dietzel Enterprises, Inc.: OSHA inspections and violations

Accomac, Virginia · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
5citation items
$11,289current penalties
Apr 24, 2019last inspection

OSHA inspectors have visited Dietzel Enterprises, Inc. in Virginia one time.

It opened on Apr 24, 2019 after a fatality or catastrophe, in Accomac.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The proposed penalties came to $28,595; today they stand at $11,289, 61% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Dietzel Enterprises, Inc. averages $11,289 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Dietzel Enterprises, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Dietzel Enterprises, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343971289 OPENED APR 24, 2019Closed

Fatality or catastrophe · Partial · Safety · 25 employees at the site · Closed Aug 10, 2020

23323 Wise Court, Accomac, VA 23301 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 22, 2019 (fatal): Employee is killed when hoist cable contacts power line

At 5:34 p.m. on April 22, 2019, an employee was pulling the hoist cable of a Soilmec SR-30 Hydraulic Rotary Rig, with a pair of shakeout hook spreaders attached to the weight ball hook, to hook up a large metal pipe sleeve. The employee was killed when he pulled the hoist cable into a 13kV overhead high voltage power line and was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.1408(a)(2)(i) · Power line safety (up to 350 kV)—equipment operations
Serious$12,725$8,908Oct 18, 2019Final
Citation 1, item 2b Serious$12,725$0Oct 18, 2019Final
Citation 1, item 3
29 CFR 1926.1410(b) · Power line safety (all voltages)—equipment operations closer than the Table A zone
Serious$2,545$1,782Oct 18, 2019Final
Citation 1, item 4
29 CFR 1926.1412(f)(2) · Inspections
Other-than-serious$600$600Oct 18, 2019Final
Citation 2, item 1
29 CFR 1926.1428(a)(3) · Signal person qualifications
Other-than-serious$0$0Oct 18, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1408 · Power line safety (up to 350 kV)—equipment operations

29 CFR 1926.1408(a)(2)(i)

(i) Option (1)—Deenergize and ground. Confirm from the utility owner/operator that the power line has been deenergized and visibly grounded at the worksite.

29 CFR 1926.1410 · Power line safety (all voltages)—equipment operations closer than the Table A zone

29 CFR 1926.1410(b)

(b) The employer determines that, after consultation with the utility owner/operator, it is infeasible to deenergize and ground the power line or relocate the power line.

29 CFR 1926.1412 · Inspections

29 CFR 1926.1412(f)(2)

(2) In addition, at least every 12 months, the equipment must be inspected by a qualified person. Disassembly is required, as necessary, to complete the inspection. The equipment must be inspected for all of the following:

29 CFR 1926.1428 · Signal person qualifications

29 CFR 1926.1430 · Training

Other poured concrete foundation and structure contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.