OSHA SearchOSHA records by employer

Discount Renovations, Inc.: OSHA inspections and violations

Houston, Texas · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
4citation items
$10,000current penalties
Jun 3, 2017last inspection

Discount Renovations, Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Jun 3, 2017 on a referral, in Houston.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $27,887 in penalties. After settlements and reviews the total is $10,000, down 64%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Discount Renovations, Inc. averages $10,000 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Discount Renovations, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Discount Renovations, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342371531 OPENED JUN 3, 2017Closed

Referral · Partial · Safety · 5 employees at the site · Closed Apr 11, 2023

1619 E. Richey Rd., Houston, TX 77073 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 3, 2017: Employee removing trench walls injured in collapse

At 10:00 a.m. on June 3, 2017, Employee #1, part of a work crew employed by a construction company, was working in a trench at a commercial building construction site. He and his coworkers, in preparation for erecting a cinder block retaining wall, were removing the trench's concrete protective walls. One side of the trench collapsed, toppling onto and trapping Employee #1. Emergency services were called and the fire department personnel were able to pull Employee #1 from the collapsed section of the trench. They then transported him to the hospital. Employee #1 was admitted and treated for forehead lacerations, bruising, and temporary loss of consciousness.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$8,873$4,000Sep 11, 2017Final
Citation 1, item 2b
29 CFR 1926.651(i)(1) · Excavations
Serious$6,338$0Sep 11, 2017Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$6,338$3,000Sep 11, 2017Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,338$3,000Sep 11, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 3, 2017, Houston: Hospitalization · intracranial injuries, unspecified · brain

On 6/3/2017, an employee was working in a trench to erect a retaining wall to insert a large machine. During the work process, the concrete company had to remove the trench walls so that the work crew inside the trench could apply mortar to a pre-set area where the cinder blocks were to be placed. As the concrete crew removed the walls, the side of the trench collapsed and toppled onto the…

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.