OSHA SearchOSHA records by employer

Display Source Alliance LLC: OSHA inspections and violations

Mesquite, Texas · Other Fabricated Wire Product Manufacturing · NAICS 332618

2inspections
5citation items
$32,974current penalties
Nov 2, 2016last inspection

OSHA has inspected Display Source Alliance LLC 2 times in Texas since 2016.

The latest one began on Nov 2, 2016 on a referral, in Mesquite.

Those inspections ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $51,575 and now stand at $32,974, 36% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Display Source Alliance LLC averages $16,487 (2 cited inspections).

Display Source Alliance LLC also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Display Source Alliance LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Display Source Alliance LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341886109 OPENED NOV 2, 2016Closed

Referral · Partial · Safety · 140 employees at the site · Closed May 31, 2017

1371 S. Town East Blvd., Mesquite, TX 75149 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$10,755$1,000Feb 23, 2017Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$12,548$7,500Feb 23, 2017Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$12,548$8,750Feb 23, 2017Final

Inspection 341705796 OPENED AUG 16, 2016Closed

Complaint · Partial · Safety · 144 employees at the site · Closed Oct 27, 2016

1371 S. Town East Boulevard, Mesquite, TX 75149 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.255(b)(4) · Resistance welding
Serious$11,224$11,224Oct 3, 2016Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$4,500$4,500Oct 3, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Mesquite site logged 8 recordable injuries or illnesses among about 130 workers: 5.9 per 100 full-time workers, against a median of 3.3 for its industry. Those cases cost 97 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Display Source Alliance,LLC
Mesquite · 2017
130 815.93.3

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 27, 2016, Mesquite: Amputation · amputations · fingertip(s)

Employee was operating a brake press when she placed her fingers in the press brake die opening during the downward stroke of the ram and amputated three fingertips on her left hand.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.255 · Resistance welding

Other other fabricated wire product manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.