OSHA SearchOSHA records by employer

Diversified Home and Business Services LLC: OSHA inspections and violations

Wilton Manors, Florida · Janitorial Services · NAICS 561720

1inspections
2citation items
$4,774current penalties
Mar 6, 2019last inspection

OSHA has inspected Diversified Home and Business Services LLC once in Florida.

The inspection began on Mar 6, 2019 on a referral, in Wilton Manors.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $7,956 and now stand at $4,774, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,232, and Diversified Home and Business Services LLC averages $4,774 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Diversified Home and Business Services LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

315employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Diversified Home and Business Services LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343832127 OPENED MAR 6, 2019Closed

Referral · Partial · Safety · 2 employees at the site · Closed Nov 14, 2019

1932 Coral Gardens Drive, Wilton Manors, FL 33306 · Janitorial Services · OSHA's record · Phone and website on Google Maps

Incident on Mar 1, 2019: Employee incurs burns while refueling pressure washer

At 12:00 p.m. on March 1, 2019, an employee was operating a gasoline powered pressure washer to clean a driveway. The employee was in the process of refueling/restarting the pressure washer when it caught on fire, resulting in third degree burns to the body.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$3,978$2,387Aug 27, 2019Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,978$2,387Aug 27, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 1, 2019, Wilton Manors: Hospitalization · heat (thermal) burns, unspecified · multiple body parts, n.e.c.

On March 1, 2019, an employee was restarting a pressure washer after refueling it when the pressure washer caught on fire. The employee suffered burns to 20-22% of his body including the left arm and shoulder, the chest and upper back.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

Other janitorial services employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.