Diverzify Pro, LLC: OSHA inspections and violations

Chicago, Illinois · Flooring Contractors · NAICS 238330

1inspections
3citation items
$10,000current penalties
Feb 21, 2024last inspection

OSHA inspectors have visited Diverzify Pro, LLC in Illinois one time.

It opened on Feb 21, 2024, in Chicago.

In all, OSHA issued 3 citation items: 3 other-than-serious.

The proposed penalties came to $32,262; today they stand at $10,000, 69% less.

The rule cited most here is 1926.416 (electrical safety in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Diverzify Pro, LLC averages $10,000 across 1 cited inspection.

Diverzify Pro, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Diverzify Pro, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347300303 OPENED FEB 21, 2024Closed

Unprogrammed other · Partial · Safety · 28 employees at the site · Closed Feb 3, 2025

151 E. Wacker Dr., Chicago, IL 60601 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$16,131$10,000Jul 24, 2024Final
Citation 1, item 1b
29 CFR 1926.416(a)(1) · Electrical safety in construction
Other-than-serious$0$0Jul 24, 2024Final
Citation 1, item 1c
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$16,131$0Jul 24, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.