OSHA SearchOSHA records by employer

DM Emm LLC: OSHA inspections and violations

Stewartstown, Pennsylvania · Siding Contractors · NAICS 238170

1inspections
8citation items
$7,459current penalties
Apr 25, 2022last inspection

OSHA has inspected DM Emm LLC once in Pennsylvania.

The inspection began on Apr 25, 2022 after a complaint, in Stewartstown; the case is still open.

That inspection ended with 8 citation items: 8 serious.

Penalties were first proposed at $7,459 and still stand at $7,459.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and DM Emm LLC averages $7,459 (1 cited inspection).

DM Emm LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch DM Emm LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345916969 OPENED APR 25, 2022Open

Complaint · Partial · Safety · 3 employees at the site · Open

17590 Kurtz School Road, Stewartstown, PA 17363 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$4,351$4,351Jul 5, 2022Final
Citation 1, item 1b
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Serious$0$0Jul 5, 2022Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jul 5, 2022Final
Citation 1, item 1d
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Jul 5, 2022Final
Citation 1, item 1e
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jul 5, 2022Final
Citation 1, item 1f
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jul 5, 2022Final
Citation 1, item 2a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,108$3,108Jul 5, 2022Final
Citation 1, item 2b
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Jul 5, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in Pennsylvania