OSHA SearchOSHA records by employer

DMMH LLC: OSHA inspections and violations

Christiansburg, Virginia · Medicinal and Botanical Manufacturing · NAICS 325411

1inspections
21citation items
$7,640current penalties
Aug 11, 2022last inspection

OSHA inspectors have visited DMMH LLC in Virginia one time.

It opened on Aug 11, 2022 after a complaint, in Christiansburg.

In all, OSHA issued 21 citation items: 17 serious and 4 other-than-serious.

The proposed penalties came to $15,280; today they stand at $7,640, 50% less.

The rule cited most here is 1910.106 (flammable liquids), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. DMMH LLC averages $7,640 across 1 cited inspection.

DMMH LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites DMMH LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346138514 OPENED AUG 11, 2022Closed

Complaint · Partial · Health · 5 employees at the site · Closed Dec 11, 2023

1771 Flanagan Drive, Christiansburg, VA 24073 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(2)(ii)(b) · Flammable liquids
Serious$2,410$1,205Dec 14, 2022Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Dec 14, 2022Final
Citation 1, item 1c
29 CFR 1910.106(e)(9)(i) · Flammable liquids
Serious$0$0Dec 14, 2022Final
Citation 1, item 1d
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Dec 14, 2022Final
Citation 1, item 2
29 CFR 1910.106(e)(7)(i)(c) · Flammable liquids
Serious$2,410$1,205Dec 14, 2022Final
Citation 1, item 3a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$1,840$920Dec 14, 2022Final
Citation 1, item 3b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Dec 14, 2022Final
Citation 1, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,265$633Dec 14, 2022Final
Citation 1, item 4b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 14, 2022Final
Citation 1, item 4c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Dec 14, 2022Final
Citation 1, item 5
29 CFR 1910.151(b) · First aid and eyewash
Serious$1,840$920Dec 14, 2022Final
Citation 1, item 6
29 CFR 1910.151(c) · First aid and eyewash
Serious$2,410$1,205Dec 14, 2022Final
Citation 1, item 7
29 CFR 1910.1450(e)(1)(i) · Occupational exposure to hazardous chemicals in laboratories
Serious$1,265$632Dec 14, 2022Final
Citation 1, item 8a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,840$920Dec 14, 2022Final
Citation 1, item 8b
29 CFR 1910.1200(f)(10) · Hazard communication
Serious$0$0Dec 14, 2022Final
Citation 1, item 8c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Dec 14, 2022Final
Citation 1, item 8d
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Dec 14, 2022Final
Citation 2, item 1
29 CFR 16VAC25-60-120
Other-than-serious$0$0Dec 14, 2022Final
Citation 2, item 2
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Dec 14, 2022Final
Citation 2, item 3
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Dec 14, 2022Final
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 14, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.37 · Exit routes

Other medicinal and botanical manufacturing employers in Virginia