OSHA SearchOSHA records by employer

DN Contractors, Inc.: OSHA inspections and violations

Morristown, New Jersey · Framing Contractors · NAICS 238130

4inspections
8citation items
$25,820current penalties
Jan 30, 2020last inspection

Since 2019, OSHA inspectors have visited DN Contractors, Inc. in New Jersey 4 times.

The most recent inspection opened on Jan 30, 2020 as a planned inspection, in Cherry Hill.

In all, OSHA issued 8 citation items: 8 serious.

The penalties, $25,820 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. DN Contractors, Inc. averages $6,455 across 4 cited inspections.

DN Contractors, Inc.: OSHA citation items per year, 2019 to 2020
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

15 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch DN Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344605738 OPENED JAN 30, 2020Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 24, 2023

1715 Springdale Road, Cherry Hill, NJ 08003 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,181$3,181Mar 17, 2020Final

Inspection 344509393 OPENED DEC 13, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 7, 2023

#7 Braeburn Court, Mahwah, NJ 07430 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,453$4,453Feb 7, 2020Final

Inspection 344480652 OPENED NOV 25, 2019Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Sep 30, 2025

191 E Hanover Ave, Morris Plains, NJ 07950 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,978$3,978Dec 20, 2019Final

Inspection 344377478 OPENED OCT 15, 2019Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jul 13, 2023

Building 7, Colgate Drive The Collection At Morristown-lennar Homes, Morristown, NJ 07960 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,273$2,273Nov 29, 2019Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$2,273$2,273Nov 29, 2019Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$2,842$2,842Nov 29, 2019Final
Citation 1, item 4
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$2,842$2,842Nov 29, 2019Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,978$3,978Nov 29, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.