OSHA SearchOSHA records by employer

DN General Contractors, LLC: OSHA inspections and violations

Woodbridge, Virginia · Masonry Contractors · NAICS 238140

1inspections
6citation items
$1,855current penalties
May 23, 2017last inspection

DN General Contractors, LLC has one OSHA inspection on record in Virginia.

OSHA opened it on May 23, 2017 as a planned inspection, in Woodbridge, and the case has not closed yet.

From that inspection OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA proposed $1,855 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. DN General Contractors, LLC averages $1,855 over 1 cited inspection in that time.

DN General Contractors, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch DN General Contractors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342346566 OPENED MAY 23, 2017Open

Planned · Partial · Safety · 3 employees at the site · Open

2680 Opitz Blvd, Woodbridge, VA 22191 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$855$855Aug 16, 2017Final
Citation 1, item 1b
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$0$0Aug 16, 2017Final
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 16, 2017Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$0$0Aug 16, 2017Final
Citation 1, item 1e
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 16, 2017Final
Citation 2, item 1
29 CFR 16VAC25-60-307.E.1
Other-than-serious$1,000$1,000Apr 4, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.454 · Scaffold training