Dorian Trejo Gonzalez: OSHA inspections and violations

Jacksonville, Florida · Framing Contractors · NAICS 238130

3inspections
3citation items
$66,237current penalties
Jan 10, 2022last inspection

OSHA has inspected Dorian Trejo Gonzalez 3 times in Florida since 2020.

The latest one began on Jan 10, 2022, in Jacksonville; the case is still open.

Those inspections ended with 3 citation items: 1 serious and 2 repeat.

Penalties were first proposed at $67,856 and now stand at $66,237, 2% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dorian Trejo Gonzalez averages $22,079 (3 cited inspections).

Dorian Trejo Gonzalez: OSHA citation items per year, 2020 to 2022
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

41 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Dorian Trejo Gonzalez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345721179 OPENED JAN 10, 2022Open

Unprogrammed other · Partial · Safety · 13 employees at the site · Open

780 Island Point Dr., Jacksonville, FL 32218 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$31,904$31,904Feb 11, 2022Final

Inspection 345728976 OPENED DEC 29, 2021Open

Complaint · Complete · Safety · 4 employees at the site · Open

780 Island Point Drive Ste 227, Jacksonville, FL 32218 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$31,904$31,904Apr 28, 2022Final

Inspection 344714142 OPENED MAR 24, 2020Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Aug 18, 2020

200 Page Bacon Road Renaissance At Santa Rosa, Mary Esther, FL 32569 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,048$2,429Jun 22, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.