OSHA SearchOSHA records by employer

Dornbos Sign Inc: OSHA inspections and violations

Charlotte, Michigan · Sign Manufacturing · NAICS 339950

1inspections
9citation items
$500current penalties
Feb 11, 2020last inspection

OSHA has inspected Dornbos Sign Inc once in Michigan.

The inspection began on Feb 11, 2020 as a planned inspection, in Charlotte.

That inspection ended with 9 citation items: 2 serious and 7 other-than-serious.

Penalties were first proposed at $1,000 and now stand at $500, 50% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dornbos Sign Inc averages $500 (1 cited inspection).

Dornbos Sign Inc: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

653employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Dornbos Sign Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344619853 OPENED FEB 11, 2020Closed

Planned · Complete · Safety · 14 employees at the site · Closed Mar 16, 2020

619 W Harris St, Charlotte, MI 48813 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10727(1)
Serious$500$250Feb 19, 2020Final
Citation 1, item 2
29 CFR 408.12631(1)
Serious$500$250Feb 19, 2020Final
Citation 2, item 1a
29 CFR 408.10121(1)
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 1b
29 CFR 408.11115(1)
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 2
29 CFR 408.10685(3)
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 3
29 CFR 408.12154(1)
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 4a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 4b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 4c
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Other-than-serious$0$0Feb 19, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(3)(ii)

(ii) Attachment plugs and receptacles may not be connected or altered in a manner which would prevent proper continuity of the equipment grounding conductor at the point where plugs are attached to receptacles. Additionally, these devices may not be altered to allow the grounding pole of a plug to be inserted into slots intended for connection to the current-carrying conductors.