OSHA SearchOSHA records by employer

Dowbuilt Inc.: OSHA inspections and violations

Malibu, California · Commercial and Institutional Building Construction · NAICS 236220

2inspections
2citation items
$2,060current penalties
Jun 6, 2019last inspection

Since 2019, OSHA inspectors have visited Dowbuilt Inc. in California 2 times.

The most recent inspection opened on Jun 6, 2019 after an accident, in Malibu.

In all, OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

The proposed penalties came to $17,810; today they stand at $2,060, 88% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Dowbuilt Inc. averages $2,060 across 1 cited inspection.

Dowbuilt Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Dowbuilt Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344063292 OPENED JUN 6, 2019Closed

Accident · Partial · Safety · 200 employees at the site · Closed Feb 9, 2021

28116 W Pacific Coast Highway, Malibu, CA 90265 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Incident on May 13, 2019: Employee's finger is amputated during forming work

At 10:15 a.m. on May 13, 2019, Employee #1 was performing a concrete form assembly for a wall at a residential construction project. Working from a scissor lift at a height of approximately 20 feet, he was inserting coil-rods into a wooden form with ?-inch pre-drilled holes. The employee was wearing Atlas 370 nitrile coated nylon gloves. Employee #1 inserted the 5-foot long threaded fiberglass coil rod into a DeWalt 20 V Max cordless power drill/driver and tightened by using the chuck, similar to the way a bit is inserted into a drill. Then, the employee used his left hand to hold the drill/driver and his free right hand to guide the coil rod into the hole of the form. The tip of the employee's glove became caught in the threads of the fiberglass coil rod, and the glove was spun around the coil, twisting tightly and amputating a portion of the right index finger. The employee was transported to the hospital and admitted for treatment of the amputation of the index finger at the distal interphalangeal joint with residual bone fragments.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3384(A)
Other-than-serious$935$935Nov 13, 2019Final
Citation 2, item 1
29 CFR 1509(A)
Serious$16,875$1,125Nov 13, 2019Final

Inspection 344022140 OPENED MAY 20, 2019Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Jul 10, 2019

28126 Pacific Coast Highway, Malibu, CA 90265 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

Other commercial and institutional building construction employers in California

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.