Inspection 344098306 OPENED JUN 20, 2019Closed
14010 Homestead Road, Humble, TX 77396 · Full-Service Restaurants · OSHA's record · Phone and website on Google Maps
Incident on Jun 19, 2019 (fatal): Employee attempts to reset deep fryer and is electrocuted
At 11:47 a.m. on June 19, 2019, an employee and coworker were in the kitchen, preparing food for lunchtime rush orders and opening the restaurant for business. When the coworker noticed that the Frymaster Model Sr14ESD deep fryer wasn't heating up the grease. The employee crawled under the deep fryer in order to reach the reset button and, when attempting to reset the internal breaker, received an electric shock and was electrocuted.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $3,978 | $3,978 | Sep 26, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $3,978 | $3,978 | Sep 26, 2019 | Final |