OSHA SearchOSHA records by employer

Driver Construction Company, Inc.: OSHA inspections and violations

Athens, Georgia · Commercial and Institutional Building Construction · NAICS 236220

6inspections
15citation items
$11,875current penalties
Dec 2, 2015last inspection

OSHA has inspected Driver Construction Company, Inc. 6 times in Georgia since 1977.

The latest one began on Dec 2, 2015 as part of a related case, in Athens.

Those inspections ended with 15 citation items: 14 serious and 1 other-than-serious.

Penalties were first proposed at $19,000 and now stand at $11,875, 38% lower after settlements or reviews.

Scope, application, and definitions applicable to this subpart comes up most often in these citations: 4 items under 1926.500.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Driver Construction Company, Inc. averages $4,900 (1 cited inspection).

Driver Construction Company, Inc.: OSHA citation items per year, 1977 to 2015
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Driver Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341121119 OPENED DEC 2, 2015Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Feb 23, 2016

3010 Atlanta Hwy, Athens, GA 30606 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$4,900$4,900Jan 22, 2016Final

Inspection 312527070 OPENED JUN 17, 2009Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 7, 2009

125 Pine Needle Drive, Athens, GA 30606 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$450$450Jun 22, 2009Closed
Citation 1, item 2
29 CFR 1926.454(c)(3) · Scaffold training
Serious$450$450Jun 22, 2009Closed
Citation 1, item 3
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$450$450Jun 22, 2009Closed

Inspection 106512247 OPENED NOV 9, 1993Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 16, 1993

1540 Monroe Drive, Gainesville, GA 30507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$1,125$0Nov 29, 1993Closed
Citation 1, item 2a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,125$1,125Nov 29, 1993Closed
Citation 1, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Nov 29, 1993Closed
Citation 1, item 3a
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$3,000$3,000Nov 29, 1993Closed
Citation 1, item 3b
29 CFR 1926.500(b)(2) · Scope, application, and definitions applicable to this subpart
Serious$0$0Nov 29, 1993Closed
Citation 2, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$6,000$0Nov 29, 1993Closed

Inspection 110073673 OPENED JAN 31, 1992Closed

Planned · Complete · Safety · 7 employees at the site · Closed May 12, 1992

170 Oneta Street, Athens, GA 30601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$1,125$1,125Apr 15, 1992Closed

Inspection 110114121 OPENED OCT 30, 1991Closed

Referral · Complete · Safety · 13 employees at the site · Closed Jan 8, 1992

Green Street, Athens, GA 30601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$375$375Dec 17, 1991Closed

Inspection 13075551 OPENED AUG 9, 1977Closed

Accident · Complete · Safety · 7 employees at the site · Closed Oct 11, 1977

Route 78, Loganville, GA 30249 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$0$0Aug 30, 1977Closed
Citation 1, item 2a
29 CFR 1926.401(a)(1) · [Reserved]
Serious$0$0Aug 30, 1977Closed
Citation 1, item 2b
29 CFR 1926.402(a)(5) · Applicability
Serious$0$0Aug 30, 1977Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(9)

(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.

29 CFR 1926.401 · [Reserved]

29 CFR 1926.402 · Applicability

29 CFR 1926.402(a)(5)

(a) Covered. Sections 1926.402 through 1926.408 contain installation safety requirements for electrical equipment and installations used to provide electric power and light at the jobsite. These sections apply to installations, both temporary and permanent, used on the jobsite; but these sections do not apply to existing permanent installations that were in place before the construction activity commenced.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other commercial and institutional building construction employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.