OSHA SearchOSHA records by employer

Dryden DPW: OSHA inspections and violations

Dryden, New York · Highway, Street, and Bridge Construction · NAICS 237310

2inspections
5citation items
$0current penalties
Jan 3, 2017last inspection

OSHA has inspected Dryden DPW 2 times in New York since 2016.

The latest one began on Jan 3, 2017 to follow up on an earlier case, in Dryden.

Those inspections ended with 5 citation items: 2 serious and 3 other-than-serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dryden DPW averages $0 (1 cited inspection).

Dryden DPW: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Dryden DPW again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342004918 OPENED JAN 3, 2017Closed

Follow-up · Partial · Safety · Local government · 6 employees at the site · Closed Jan 3, 2017

64 South St., Dryden, NY 13053 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341744464 OPENED AUG 31, 2016Closed

Planned · Complete · Safety · Local government · 6 employees at the site · Closed Jan 3, 2017

64 South St, Dryden, NY 13053 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Serious$0$0Nov 16, 2016Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Nov 16, 2016Final
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Nov 16, 2016Final
Citation 2, item 2
29 CFR 12 NYCRR PART 800.6(E)(1)(I)
Other-than-serious$0$0Nov 16, 2016Final
Citation 2, item 3
29 CFR 12 NYCRR PART 801.40(A)
Other-than-serious$0$0Nov 16, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.244(a)(1)(ii)

(ii) The rated load shall be legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other highway, street, and bridge construction employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.