OSHA SearchOSHA records by employer

Dryvit Systems, Inc.: OSHA inspections and violations

West Warwick, Rhode Island · All Other Miscellaneous Chemical Product and Preparation Manufacturing · NAICS 325998

3inspections
17citation items
$5,960current penalties
Sep 27, 2017last inspection

Since 1998, OSHA inspectors have visited Dryvit Systems, Inc. in Rhode Island 3 times.

The most recent inspection opened on Sep 27, 2017 on a referral, in Cranston.

In all, OSHA issued 17 citation items: 11 serious and 6 other-than-serious.

The proposed penalties came to $12,072; today they stand at $5,960, 51% less.

The rule cited most here is 1910.132 (personal protective equipment, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Dryvit Systems, Inc. averages $2,535 across 1 cited inspection.

Dryvit Systems, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Dryvit Systems, Inc.: OSHA citation items per year, 1998 to 2017
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

84employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Dryvit Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342667441 OPENED SEP 27, 2017Closed

Referral · Partial · Safety · 25 employees at the site · Closed Nov 30, 2017

200 First Avenue, Cranston, RI 02910 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Sep 27, 2017: Employee amputates finger when clearing a jam from a multi-s

At 8:45 a.m. on September 27, 2017, an employee was loading sticks of material into a Multi-Saw so they could be fed into the saw blade and be cut to size. The saw became jammed and the employee opened a guide door hatch that allowed access to the bottom of the machine loading and feeding area while the saw blades were operating. The employee reached into the feeding chamber and used her fingers to try and adjust the jammed stick. The pneumatic feed system pushed air into the chamber and the employee's left index finger was pushed into the rotating saw blades. The employee amputated her index finger just past the first knuckle.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,622$2,535Nov 2, 2017Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Serious$0$0Nov 2, 2017Final

Inspection 302670377 OPENED DEC 4, 2000Closed

Complaint · Partial · Safety · 83 employees at the site · Closed Feb 9, 2001

1 Energy Way, West Warwick, RI 02893 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$2,125$1,062Dec 19, 2000Closed
Citation 1, item 1b
29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements
Serious$0$0Dec 19, 2000Closed
Citation 1, item 1c
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Serious$0$0Dec 19, 2000Closed
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,700$50Dec 19, 2000Closed
Citation 1, item 3a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,700$850Dec 19, 2000Closed
Citation 1, item 3b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 19, 2000Closed
Citation 2, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Dec 19, 2000Closed
Citation 2, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 19, 2000Closed
Citation 2, item 3
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Dec 19, 2000Closed
Citation 2, item 4
29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Dec 19, 2000Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 19, 2000Closed
Citation 2, item 6
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Dec 19, 2000Closed

Inspection 300096153 OPENED FEB 27, 1998Closed

Complaint · Partial · Health · 30 employees at the site · Closed Jun 11, 1998

1 Energy Way, West Warwick, RI 02893 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,625$812May 21, 1998Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,300$650May 21, 1998Closed
Citation 1, item 2b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 21, 1998Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the West Warwick site logged 2 recordable injuries or illnesses among about 59 workers: 2.4 per 100 full-time workers, against a median of 2.0 for its industry. Those cases cost 1 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Dryvit Systems, Inc.
West Warwick · 2021
59 212.42.0
Dryvit systems
West Warwick · 2020
87 434.32.0
NewBrick Cranston
Cranston · 2018
55 336.22.0
Dryvit West Warwick
West Warwick · 2018
45 000.02.0

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Sep 27, 2017, Cranston: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was loading sticks of material into a multi-saw when a stick became jammed as it was being fed it into the saw blade area. She opened a side door hatch to access the feed compartment and used her fingers to try and adjust the jammed stick. The machine s pneumatic feeding system pushed air into the material feed compartment, which then pushed the stick and the employee s left index…

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.305 · Electrical wiring methods

Other all other miscellaneous chemical product and preparation manufacturing employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.