OSHA SearchOSHA records by employer

DTCM LLC: OSHA inspections and violations

Louisville, Kentucky · Commercial and Institutional Building Construction · NAICS 236220

2inspections
13citation items
$67,000current penalties
Apr 6, 2018last inspection

DTCM LLC has 2 OSHA inspections on record in Kentucky, the first in 2017.

OSHA's last visit started on Apr 6, 2018 after a complaint, in Louisville.

Across those inspections OSHA issued 13 citation items: 12 serious and 1 willful.

OSHA proposed $67,000 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. DTCM LLC averages $67,000 over 1 cited inspection in that time.

DTCM LLC: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

182employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch DTCM LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343069332 OPENED APR 6, 2018Closed

Complaint · No inspection · Safety · Closed Apr 6, 2018

3000 Crittenden Dr., Louisville, KY 40209 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342296878 OPENED MAY 2, 2017Open

Referral · Partial · Safety · 2 employees at the site · Open

3000 Crittenden Dr., Louisville, KY 40209 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Willful$35,000$35,000Oct 26, 2017Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 2
29 CFR 1926.252(a) · Disposal of waste materials
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 3
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 5
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 6a
29 CFR 1926.501(b)(4)(iii) · Fall protection in construction
Serious$2,500$2,500Oct 26, 2017Final
Citation 2, item 6b
29 CFR 1926.502(j)(1) · Fall protection systems
Serious$0$0Oct 26, 2017Final
Citation 2, item 7a
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 7b
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0Oct 26, 2017Final
Citation 2, item 8
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,500$3,500Oct 26, 2017Final
Citation 2, item 9
29 CFR 1926.701(f) · Concrete and Masonry Construction: general requirements
Serious$2,500$2,500Oct 26, 2017Final
Citation 2, item 10
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$2,500$2,500Oct 26, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.252 · Disposal of waste materials

29 CFR 1926.252(a)

(a) Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, shall be used. For the purpose of this paragraph, an enclosed chute is a slide, closed in on all sides, through which material is moved from a high place to a lower one.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.